Architectural LED Lighting Glossary
24 terms that decide whether a facade fixture schedule is read the same way by the designer, the contractor and the purchaser. Each entry gives the definition first, then the practical consequence for input voltage, beam angle, control mode or ingress rating.
An architectural LED lighting glossary defines the terms that appear on a facade luminaire specification sheet and a project fixture BOM — beam angle, CCT, IP65/IP68, DC24V, DMX512, RGBW and co-extrusion. This one holds 24 terms drawn from the 2026 GDXC catalogues, which list 98 fixture models across 5 catalogues and 53 co-extruded flexible profiles. Each entry states what the term means and the practical consequence for a fixture schedule.
Published parameters referenced in these definitions
| Parameter | Published value |
|---|---|
| Input voltage | DC24V; AC220V on selected LED floodlights |
| Ingress rating | IP65 on most outdoor models; IP68 on underwater variants |
| Beam angles | 10°, 15°, 30°, 45°, 60°; asymmetric 10×30°, 10×45°, 10×60°, 20×60° |
| Colour | 1800–6500K; single colour, RGB, RGBW |
| Control | ON/OFF, TTL, DMX512 |
| 2026 catalogues | 5 catalogues, 98 model entries (linear 10, wall washer 20, floodlight 29, in-ground 12, pixel point 27) |
| Co-extruded profiles | 53 entries: 48 neon flex, 2 wall-washer strips, 3 slim rigid bars; sections 6×6–20×20 mm, 120° emitting angle |
6
- 6063 aluminium
-
An aluminium extrusion alloy commonly used for luminaire housings because it forms thin, consistent profiles and conducts heat away from the LED board.
Catalogued wall washer housings use 6063 aluminium; the slimmer GD-WW3524 is W35 x H24 mm at 18 / 24 W while the GD-WW6036 is W60 x H36 mm at 48 / 72 W. The larger section is the thermal path for the higher wattage.
B
- Beam angle
-
The angular width of the cone of light emitted by a luminaire, measured between the points where intensity falls to half of the peak value.
Our 2026 catalogues list 10, 15, 30, 45 and 60 degree symmetric beams plus elliptical 10x30, 10x45, 10x60 and 20x60 degree options. At a 0.5 m setback, a 60 degree beam spreads far more light sideways than a 10x60 degree beam, which is why beam choice follows wall height and surface reflectance.
- BOM (Bill of Materials) — Fixture schedule
-
A project schedule listing every luminaire, accessory and control item with its model, configuration, quantity and installation zone.
A usable facade BOM records model, wattage, beam angle, colour, control mode, length, IP rating, quantity and zone per line. Omitting the input voltage is a common error: DC24V and AC220V variants cannot share one circuit.
- Batch consistency
-
The degree to which colour temperature, brightness and RGB output match between luminaires produced in the same production batch.
Facade projects show visible colour differences when fixtures from different batches are installed side by side on one elevation. We group fixtures for a single visible elevation by production batch and check them before packing; a later top-up order is flagged as a mismatch risk.
C
- CCT (Correlated Colour Temperature)
-
The perceived warmth or coolness of a white light source, expressed in kelvin (K).
Catalogued single-colour variants cover 1800-6500 K. Lower values suit warm hospitality elevations, higher values suit cool commercial facades; the final choice depends on facade material and the surrounding master plan, not on a product name.
- Co-extrusion
-
A manufacturing process in which the LED strip and its silicone outer jacket are formed together into one continuous sealed profile.
The documented range contains 53 entries: 48 neon flex profiles, 2 wall-washer strips and 3 slim rigid bars, with sections from 6x6 mm to 20x20 mm. A field-cut end must be resealed with the correct cap and potting or the profile is no longer IP-rated.
D
- DC24V
-
A 24 volt direct-current supply commonly used for low-voltage outdoor architectural luminaires.
Most catalogued wall washer, linear, pixel and in-ground families are DC24V; AC220V appears on selected floodlight rows. Long DC24V runs are sensitive to voltage drop, which depends on wattage per metre, cable gauge and feed arrangement rather than on the fixture model alone.
- Diffuser
-
A translucent front cover that spreads LED output into a continuous line and reduces the visibility of individual diodes.
Options include transparent PC, diffused PC, acrylic, silk-screened glass and perforated aluminium covers. Transparent PC gives higher on-axis output with visible dotting; diffused PC and silk-screened glass give a continuous line with lower peak intensity.
- DMX512
-
A unidirectional digital lighting control protocol that assigns channel values within a 512-channel universe.
An RGB node uses 3 channels and an RGBW node 4, so one universe holds at most 128 four-channel nodes before addressing overhead. DMX512 is listed on selected model rows only, not on every RGB fixture in the catalogue.
E
- Elliptical beam — 10x60, 20x60
-
A beam with different horizontal and vertical spreads, used to push light up a tall narrow surface without wasting it sideways.
Catalogue options include 10x30, 10x45, 10x60 and 20x60 degrees. A 10x60 degree optic is the usual starting point for a tall facade with a short mounting setback; a symmetric 60 degree beam at the same position spills much of its output off the target.
G
- Grazing
-
Lighting a surface from a very short setback with a narrow beam so that texture, joints and relief are emphasised.
Grazing is distinct from washing, which uses a wider beam from a greater setback for an even appearance. The two require different optics: a grazing effect on a 12 m wall typically starts from a narrow elliptical beam, while an even wash points toward 60 degrees.
I
- IP65
-
An ingress protection rating indicating a dust-tight enclosure protected against water jets from any direction.
IP65 is stated for most outdoor fixtures in our catalogues and must be confirmed per model. It covers rain exposure, not continuous immersion, and it does not survive an unsealed field cable termination.
- IP68
-
An ingress protection rating for enclosures rated for continuous immersion under conditions specified by the manufacturer.
IP68 appears on the underwater GD-BL-K variants and related entries. It is not a depth or duration guarantee: immersion depth, cleaning chemicals and gland potting still determine long-term performance.
L
- LED wall washer
-
A linear outdoor luminaire that washes or grazes a vertical surface from a short setback using a controlled beam.
The 2026 catalogue lists 20 wall washer models at DC24V and IP65, with 18 / 24 / 36 / 48 / 72 W options and 1000 mm nominal lengths. GD-WW3524 measures W35 x H24 x L1002 mm; GD-WW6036 measures W60 x H36 x L1000 mm for higher 48 / 72 W output.
O
- ON/OFF control
-
A non-addressable luminaire variant that is simply switched on and off, with no dimming or colour control signal.
ON/OFF, TTL and DMX512 appear on different catalogue rows. Specifying ON/OFF where a dynamic scene is expected produces a fixture that cannot be addressed; the control mode is therefore recorded per BOM line.
P
- PCB width
-
The width of the flexible printed circuit board inside a co-extruded linear profile, in millimetres.
Documented co-extruded sections use PCB widths of 4, 8, 10 or 12 mm. The 6x6 mm top-view section uses a 4 mm board and weighs 43.5 g/m, while the 6x16 mm side-view anti-break section uses a 10 mm board and weighs 109 g/m; these are representative page values, not family-wide constants.
- Pixel pitch / points per square metre
-
The spatial density of individually addressable LED nodes across a media facade surface.
Documented configurations range from 36 to 400 points per square metre. Higher density multiplies node count, cable count, DMX universes and power supply size; the pitch follows viewing distance and the smallest detail in the content.
R
- RGB
-
A three-channel colour mixing system using red, green and blue emitters.
An RGB node consumes 3 DMX channels. Mixing RGB and RGBW nodes on one facade changes the channel budget, so the variants are listed on separate BOM lines with a recalculated universe allocation.
- RGBW
-
A four-channel colour mixing system that adds a dedicated white emitter to red, green and blue.
RGBW gives cleaner white light than mixing RGB, at the cost of a fourth DMX channel. Some high-power RGBW configurations in the source tables carry a caution note and must be confirmed by model before release.
S
- Setback
-
The distance between the luminaire and the surface it illuminates.
Setback and surface reflectance are the two inputs that decide whether a 30, 60 or 10x60 degree beam holds uniformity on a given elevation. An effect photo without a setback dimension is enough to choose a product family but not to fix a beam angle or fixture count.
- Silk-screened round-hole glass
-
A 4 mm glass front cover with a printed dot pattern used to diffuse LED output and reduce glare on wall washer faces.
The GD-WW wall washer range pairs a 6063 aluminium housing with 4 mm silk-screened round-hole glass. It produces a more uniform, lower-glare wall wash than a transparent PC cover, at the cost of some peak output.
T
- TTL control
-
A logic-level signal variant listed on certain catalogue rows, distinct from addressable DMX512 control.
TTL and ON/OFF rows appear alongside DMX512 entries in the source catalogues. Confirming the control mode per model row prevents a controller being specified for a fixture that cannot respond to it.
U
- Universe (DMX)
-
One 512-channel DMX512 data block, the basic unit used to size controllers and cabling.
At 4 channels per RGBW node, a universe holds at most 128 such nodes before overhead. Long facades and bridge decks normally need multiple universes plus intermediate power injection; the channel budget is issued with the BOM.
V
- Voltage drop
-
The reduction in supply voltage along a cable caused by its resistance and the current drawn by the connected luminaires.
Voltage drop depends on wattage per metre, cable gauge and feed arrangement, not on the fixture model. The catalogue records 160 mm wire spacing and 30 pixels per string on certain pixel products as descriptions, not field limits; the site engineer calculates the actual run.
Definitions follow the terminology used in the 2026 GDXC product catalogues and the project fixture BOM. Where a value differs between model rows — DC24V versus AC220V, IP65 versus IP68, RGB versus RGBW — the detail paragraph states which variant it applies to. Worked examples are in the knowledge base and across the six product families.
Scope boundary — GDXC supplies outdoor architectural and landscape LED lighting and DMX512 control systems only. We do not supply indoor residential lighting, road or tunnel main lighting, or bare LED chips and emitters. We do not publish client drawings, customer names or named project references, and we do not claim unverified certifications, fixed lead times, fixed prices or warranty periods. Final fixture selection, quotation and installation are confirmed between the client and our technical team.
Send your facade drawings or lighting effect renders
Share an elevation drawing, an effect render or a draft fixture list. Our project engineers return a fixture BOM, beam-angle and optical distribution suggestions, and DMX512 addressing coordination. Final selection, quotation and installation are confirmed with your technical team.