How to Specify Linear LED Light for Building Outlines
How to specify linear LED light for building outlines: lengths, beam angles, power classes, colour systems and control lines to confirm.
GDXC Project Engineering · Published October 20, 2026 · 7 min read
A linear LED light is an elongated architectural luminaire used to trace building outlines, edges and reveals as a continuous line of light. GDXC documents the GD-L and GD-U series within 10 architectural linear light model entries, with common lengths of 1000 / 500 / 260 mm, DC24V supply on most low-voltage models, IP65 for most outdoor use, and single-colour 1800–6500K, RGB or RGBW with ON/OFF, TTL or DMX512 control.
Key points
- Linear LED outline fixtures use common lengths of 1000 / 500 / 260 mm, with 10 architectural linear light model entries.
- Beam options include 10°, 15°, 30°, 45°, 60° and asymmetric 10×30°, 10×45°, 10×60°, 20×60°, even on an outline run.
- Rigid profiles use 6063 aluminium with 4 mm silk-screen round-hole glass; co-extruded sections run 6×6 mm to 20×20 mm.
- Control protocol ON/OFF, TTL or DMX512 is fixed at order stage and cannot be changed after installation.
Short answer
A linear LED light is an elongated architectural luminaire used to trace building outlines, edges and reveals as a continuous line of light. GDXC documents the GD-L and GD-U series within 10 architectural linear light model entries, with common lengths of 1000 / 500 / 260 mm, DC24V supply on most low-voltage models, IP65 for most outdoor use, and single-colour 1800–6500K, RGB or RGBW with ON/OFF, TTL or DMX512 control.
What an outline specification must contain
A building outline is a continuous line, so the specification fails at the seams rather than in the middle of a run. The lines below are the ones that must be fixed before a BOM is released; each is independent, and each is confirmed per model.
| BOM line | Documented options | Why it matters on an outline |
|---|---|---|
| Family | GD-L / GD-U architectural linear lights | 10 model entries in 2026 catalogues |
| Length | 1000 / 500 / 260 mm common lengths | Sets the joint pattern |
| Supply | DC24V most low-voltage models; AC220V some floodlights | Voltage drop along the run |
| Colour | Single-colour 1800–6500K, RGB, RGBW | Static versus scene capability |
| Control | ON/OFF, TTL, DMX512 | Fixed at order stage |
| Ingress | IP65 most outdoor models; IP68 underwater items | Facade versus submerged use |
| Housing | 6063 aluminium, 4 mm silk-screen round-hole glass on relevant models | Straight-run rigidity |
GDXC’s 2026 documentation set comprises 5 product catalogues with 98 model entries in total: 10 architectural linear lights, 20 wall washers, 29 floodlights, 12 in-ground and underwater lights, and 27 pixel point lights. An outline drawing that mixes linear lights with washes therefore draws on more than one family, and the project BOM and QA review is where those lines are reconciled.
Lengths and the joint pattern
Common lengths of 1000 / 500 / 260 mm are the documented increments. On a straight elevation a 1000 mm unit gives the fewest joints; a 500 mm or 260 mm unit is useful where a window bay or corner breaks the run. Joints are visible on a continuous outline because the diffuser and the extrusion both terminate there, so the elevation drawing, not the catalogue, decides the mix.
| Length | Where it fits | Consequence |
|---|---|---|
| 1000 mm | Long unbroken edges | Fewest joints |
| 500 mm | Window bays and returns | More seams, easier setbacks |
| 260 mm | Short reveals and corners | Most seams, tightest fit |
The same length vocabulary appears on rigid wall-washer housings: GD-WW3524 at W35 × H24 × L1002 mm and 18/24 W, GD-WW4025 at W40 × H25 × L1003 mm and 24/36 W, and GD-WW6036 at W60 × H36 × L1000 mm and 48/72 W. Those are separate models with discrete driver and thermal designs; a 24/36 W unit is not a dimmed 48/72 W unit. Length therefore travels with power class in the submittal, not independently.
Optics on a linear run
An outline is often specified as if it needed no optics, but the light still has to be kept on the edge rather than spilled onto the glazing. Symmetric and asymmetric beam angles are documented options across the range.
| Beam angle | Family | Use on an outline |
|---|---|---|
| 10° | Symmetric | Tight edge or column |
| 15° | Symmetric | Narrow mullion |
| 30° | Symmetric | Standard edge wash |
| 45° | Symmetric | Short setback |
| 60° | Symmetric | Broad, low edge |
| 10×30° | Asymmetric | Medium-height return |
| 10×45° | Asymmetric | Tall return |
| 10×60° | Asymmetric | Very tall facade edge |
| 20×60° | Asymmetric | Wide and tall edge |
How to choose a beam angle for facade lighting sets out the selection logic. Angle is fixed by the optic fitted to the 6063 aluminium profile at order stage, so it cannot be tuned during commissioning; only re-aiming is possible afterwards.
Rigid profiles versus flexible strip
A curved outline cannot be built from rigid extrusions. The co-extruded flexible range is documented separately, with 53 items: 48 neon flex strips, 2 wall-washer strips and 3 ultra-thin rigid bars. Sections run from 6×6 mm to 20×20 mm, the emitting angle is 120°, and documented weights are 43.5 / 57 / 109 g/m.
| Attribute | Rigid linear profile | Co-extruded flexible strip |
|---|---|---|
| Body | 6063 aluminium profile | Co-extruded flexible section |
| Window | 4 mm silk-screen round-hole glass on relevant models | Diffused co-extrusion |
| Section | Rigid housing | 6×6 mm to 20×20 mm |
| Emitting angle | Set by fitted optic | 120° |
| Documented weight | Per model | 43.5 / 57 / 109 g/m |
| Curved runs | Straight only | Used where the outline curves |
Architectural linear lights and flexible linear lighting are separate product lines with separate documentation, and they are the two pages a specifier should cross-check before fixing the outline geometry. Co-extruded neon flex vs rigid linear profiles compares them in detail.
Electrical, colour and control on one run
Colour and control decide whether an outline is static or animated, and they are independent of length and optic. Single-colour 1800–6500K suits a fixed white edge; RGB and RGBW support colour scenes, with RGBW adding a dedicated white channel. ON/OFF and TTL cover static and fixed-pattern work, while DMX512 supports per-fixture addressing.
| Scheme | Colour system | Control | Supply note |
|---|---|---|---|
| Static white edge | Single-colour 1800–6500K | ON/OFF or TTL | DC24V most low-voltage models |
| Fixed-pattern segments | RGB | TTL | DC24V most low-voltage models |
| Colour scenes | RGB or RGBW | DMX512 | DC24V most low-voltage models |
| Animated outline | RGB or RGBW | DMX512 | DC24V most low-voltage models |
RGB vs RGBW vs single colour for facades covers the colour decision, and facade lighting BOM checklist for contractors covers the submittal lines. Facade lighting design describes how the outline is laid out with washes and accents.
Verification and commercial limits
The compliance wording available is: “CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model.” Catalogues state 50,000 hours for the source, a catalogue-stated figure, not a warranty commitment. GDXC was established in 2014 in Guangming District, Shenzhen, Guangdong Province, China, and serves the Middle East and Southeast Asia first, with Europe, North America, South America and Africa also covered. Enquiries go to chenliang@gdzm-led.com, +86 153 0264 9886 or WhatsApp 8615302649886.
What we do not cover / Limits
This article covers specification of exterior architectural linear LED outline lighting only. It does not apply to indoor residential lighting or to road and tunnel main lighting, which are outside GDXC’s scope. GDXC does not sell LED chips, packages or bare light sources and does not publish client drawings. No cut length schedule, joint detail, voltage-drop calculation, driver count, mounting bracket design or illuminance target is provided here; those must be produced by the client’s engineering personnel from the project drawings. The article does not cover submerged installations using non-IP68 models, AC220V mains floodlighting design, or curved outlines built from rigid 6063 aluminium profiles. We do not promise unverified certifications, fixed lead times or published prices, and no warranty period is offered; the 50,000 hours figure is a catalogue-stated figure, not a warranty commitment. Final fixture selection, quotation and installation work must be confirmed by the client’s own engineering team.
This article describes general practice in outdoor architectural LED lighting. It is not a substitute for a project-specific review — beam angle, IP rating and control mode must be confirmed against the fixture schedule, the elevation and the site conditions.