Quality, QA and Documentation
Batch consistency checks, per-model parameters and the documents we can provide — stated precisely enough that you can verify each claim against the fixture BOM instead of taking it on trust.
Quality control at GDXC focuses on 6 things that change how a facade reads at night: input voltage, IP rating, CCT within 1800–6500K, control mode, beam angle and batch appearance. CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model. We do not claim unverified certifications, fixed lead times or warranty periods — final fixture selection, quotation and installation are confirmed between the client and our technical team.
Documentation and its scope
A document is only useful if its scope covers the models you are buying. This table states what can be provided and what must be confirmed per model or per project.
| Document | Scope / availability | Notes |
|---|---|---|
| CE documentation | Available per model; scope confirmed per project | Documentation is matched to the specific model numbers in your fixture BOM before it is issued. |
| RoHS test report | Can be requested per model | Requested for the exact variants being ordered, not issued as a blanket company-wide statement. |
| IP test report | Can be requested per model | Relates to the declared rating — IP65 for most outdoor models, IP68 for underwater models. |
| Batch consistency record | Checked before shipment | Covers CCT within 1800–6500K, output and appearance across the batch. |
Checks performed in the workshop
| Check station | What is verified |
|---|---|
| Aging-test rack | Continuous burn-in of DC24V luminaires before packing |
| Ingress check station | Seal and gasket verification for IP65 / IP68 models |
| Optical check bench | Beam-angle verification against 10°–60° and elliptical options |
| Electrical test set | DC24V standard input; AC220V on selected floodlights |
| Control test bench | ON/OFF, TTL and DMX512 addressing verification |
| Colour and appearance review | Single colour, RGB and RGBW consistency within a batch |
How an order is checked through production
- Confirm the model list Every project starts from a fixture BOM with exact model numbers. Voltage, IP rating, CCT, control mode and beam angle are recorded per line before anything is produced.
- Incoming material check 6063 aluminium extruded housings, 4 mm silk-screened round-hole glass and diffuser covers are checked against the model specification before assembly.
- In-process electrical and optical checks Input voltage, control response and beam angle are verified during assembly. DMX512 addressing is checked against the control plan where DMX512 models are used.
- Aging and ingress checks Luminaires run on the aging-test rack, and seals are checked against the declared IP65 or IP68 rating. Underwater models are checked to the IP68 requirement.
- Batch consistency review Before shipment, CCT within 1800–6500K, output, colour (single colour / RGB / RGBW) and housing appearance are compared across the batch so a facade reads uniformly.
Documentation and reference material
- 2026 product catalogues — 5 catalogues covering 98 fixture model entries
- Per-model specification sheets (voltage, IP rating, CCT, beam angle, dimensions)
- Project fixture BOM and DMX512 addressing plan
- CAD electrical drawing and installation communication notes
- CE documentation available per model; scope confirmed per project
- RoHS and IP test reports can be requested per model
- Batch consistency record for the shipped order
Where the boundary sits
Inspection verifies conformance to a published model specification; it does not change that specification. Where a project needs a beam angle, CCT, control mode or IP rating outside the 2026 catalogue range, the correct response is a model or design change, and we will say so during selection rather than imply a capability we have not confirmed.
Scope boundary — outdoor architectural and landscape LED lighting and DMX512 control systems only. CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model. We do not claim unverified certifications, fixed lead times, fixed prices or warranty periods. Final fixture selection, quotation and installation are confirmed between the client and our technical team.
Documents, batch consistency and control
Which compliance documents can be provided?
CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model. We do not claim unverified certifications, and no certificate numbers or validity dates are published.
How do you keep a facade looking uniform?
We check CCT within 1800–6500K, output, colour (single colour, RGB or RGBW) and housing appearance across each batch before shipment, and record the result per model number.
Can documentation be matched to our exact BOM?
Yes. CE documentation, RoHS reports and IP reports are matched to the specific model numbers in your fixture schedule, because the applicable scope differs between IP65 outdoor and IP68 underwater models.
What is checked on DMX512 projects?
Control mode (ON/OFF, TTL or DMX512) and addressing are verified against the control plan before shipment, so the DMX512 channels align with the control system designer’s allocation.
Need documentation for supplier qualification?
Send your fixture BOM or model list and we will confirm which CE, RoHS and IP documentation applies per model and which scope must be agreed per project.