DMX512 vs TTL vs ON/OFF for Architectural Lighting
DMX512 vs TTL vs ON/OFF for architectural lighting: what each control option does, where RGB and RGBW fit, and how to confirm the protocol.
GDXC Project Engineering · Published October 12, 2026 · 6 min read
DMX512, TTL and ON/OFF are the documented control options for outdoor architectural luminaires. ON/OFF switches a fixture or circuit with no dimming or addressing; TTL carries a low-voltage signal for fixed-pattern segments; DMX512 assigns addresses to individual fixtures for dimming and RGB or RGBW scenes. Most low-voltage models run on DC24V, and the protocol is fixed at order stage.
Key points
- ON/OFF, TTL and DMX512 are the documented control options, and the protocol is fixed at order stage.
- DMX512 allows per-fixture addressing for RGB and RGBW scenes; ON/OFF and TTL versions cannot be re-addressed in the field.
- Colour options are single-colour 1800–6500K, RGB and RGBW, independent of the control protocol.
- Most low-voltage models are DC24V; AC220V appears on some floodlights only.
Short answer
DMX512, TTL and ON/OFF are the documented control options for outdoor architectural luminaires. ON/OFF switches a fixture or circuit with no dimming or addressing; TTL carries a low-voltage signal for fixed-pattern segments; DMX512 assigns addresses to individual fixtures for dimming and RGB or RGBW scenes. Most low-voltage models run on DC24V, and the protocol is fixed at order stage.
The documented control options
Control protocol describes how a fixture receives instructions, and it is a hardware decision rather than a software setting. GDXC documents ON/OFF, TTL and DMX512 across its outdoor architectural and landscape LED lighting range, alongside DMX512 intelligent control as a stated part of its scope since the company was established in 2014.
| Option | What it does | What it cannot do |
|---|---|---|
| ON/OFF | Switches a fixture or circuit | No dimming, no addressing, no colour scenes |
| TTL | Carries a low-voltage signal to fixed-pattern segments | No per-fixture addressing |
| DMX512 | Assigns addresses to individual fixtures for dimming and scenes | Requires an addressing plan and compatible controller |
The distinction that matters commercially is that these are separate driver configurations. ON/OFF and TTL units cannot be re-addressed as DMX512 devices after installation, so a scheme that changes from static to animated after the order is placed requires replacement hardware, not a controller update. Most low-voltage models run on DC24V, while AC220V appears on some floodlights only, so supply and protocol are independent BOM lines.
What the protocol changes on site
The control option determines what a commissioning engineer can do with a finished installation. On a static single-colour facade, ON/OFF may be sufficient; on a facade with colour scenes, DMX512 is the documented option that supports per-fixture behaviour.
| Scheme requirement | Protocol to specify | Colour system that fits |
|---|---|---|
| Static white facade, no dimming | ON/OFF | Single-colour 1800–6500K |
| Fixed-pattern segments | TTL | Single-colour 1800–6500K or RGB |
| Per-fixture dimming | DMX512 | Single-colour 1800–6500K, RGB, RGBW |
| Colour scenes across an elevation | DMX512 | RGB or RGBW |
| Animated pixel effects | DMX512 | RGB or RGBW |
RGBW adds a dedicated white channel to RGB, which is why it belongs in a DMX512 scheme rather than a switched one. Pixel point lights are documented at 36/64/100/144/256/400 points per square metre, a density figure that affects addressing and controller capacity even though the density itself is a layout decision made by the client’s designer. Ingress protection is a separate line again: IP65 covers most outdoor models, and IP68 applies to underwater items.
Supply, colour and protection, kept separate
A common submittal error is to bundle supply voltage, colour system, control protocol and ingress rating into a single part number and assume they move together. In the documented range they are independent options, which is why the project BOM and QA review checks them line by line.
| BOM line | Documented options | Confirmation point |
|---|---|---|
| Supply | DC24V most low-voltage models; AC220V some floodlights | Per model |
| Colour | Single-colour 1800–6500K, RGB, RGBW | Per model |
| Control | ON/OFF, TTL, DMX512 | Fixed at order stage |
| Ingress | IP65 most outdoor models; IP68 underwater items | Per model and per project |
| Housing | 6063 aluminium, 4 mm silk-screen round-hole glass on relevant models | Per model |
The same 6063 aluminium housing can therefore appear as a single-colour ON/OFF unit or an RGBW DMX512 unit. What cannot change after manufacturing is the control hardware, so the addressing plan belongs in the submittal rather than in a later commissioning note.
Where control meets the product families
The 2026 documentation set comprises 5 product catalogues with 98 model entries, plus a co-extruded flexible file of 53 items covering 48 neon flex strips, 2 wall-washer strips and 3 ultra-thin rigid bars. Control options are confirmed per model rather than per family, so a BOM should not assume that a series prefix implies a protocol.
| Product family | Model entries | Control note |
|---|---|---|
| Architectural linear lights | 10 | ON/OFF, TTL, DMX512 confirmed per model |
| LED wall washers | 20 | ON/OFF, TTL, DMX512 confirmed per model |
| LED floodlights | 29 | AC220V variants exist; protocol confirmed per model |
| In-ground and underwater lights | 12 | IP68 applies to underwater items |
| Pixel point lights | 27 | 36/64/100/144/256/400 points per square metre |
Common lengths of 1000 / 500 / 260 mm and the documented GD-WW sizes, W35 × H24 × L1002 mm at 18/24 W, W40 × H25 × L1003 mm at 24/36 W and W60 × H36 × L1000 mm at 48/72 W, are mechanical lines in the same BOM. A protocol change does not alter them, but a fixture replacement does.
Specifying control before the order
DMX512 control systems describes the addressing and scene architecture, while pixel point lights and LED wall washers show where animated and wash effects sit in the range. RGB vs RGBW vs single colour for facades covers the colour decision, facade lighting BOM checklist for contractors covers the submittal lines, and how to read a photometric specification covers the data that accompanies the fixtures.
The compliance wording available is: “CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model.” Catalogues state 50,000 hours for the source, a catalogue-stated figure, not a warranty commitment. Enquiries can be sent to chenliang@gdzm-led.com, +86 153 0264 9886 or WhatsApp 8615302649886; GDXC is based in Guangming District, Shenzhen, Guangdong Province, China, and serves the Middle East and Southeast Asia first, with Europe, North America, South America and Africa also covered.
What we do not cover / Limits
This article compares control protocols for exterior architectural and landscape LED lighting only. It does not apply to indoor residential lighting or to road and tunnel main lighting, which are outside GDXC’s scope. GDXC does not sell LED chips, packages or bare light sources, does not publish client drawings, and does not supply a lighting-design calculation, controller schedule, addressing table or cabling layout here. We do not promise unverified certifications, fixed lead times or published prices, and no warranty period is offered; the 50,000 hours figure is a catalogue-stated figure, not a warranty commitment. The article does not cover submerged installations using non-IP68 models or AC220V mains floodlighting design. Final protocol selection, controller specification, quotation and installation work must be confirmed by the client’s own engineering personnel.
This article describes general practice in outdoor architectural LED lighting. It is not a substitute for a project-specific review — beam angle, IP rating and control mode must be confirmed against the fixture schedule, the elevation and the site conditions.