Procurement

Facade Lighting BOM Checklist for Contractors

Facade lighting BOM checklist for contractors: the lines to confirm, from 98 catalogue entries to DC24V supply, IP ratings and DMX512 control.

GDXC Project Engineering · Published November 1, 2026 · 7 min read

Short answer

A facade lighting BOM is the itemised list of fixtures, controls and accessories that a contractor submits for approval before an order. GDXC's 2026 documentation comprises 5 product catalogues with 98 model entries plus a co-extruded flexible file of 53 items. A complete BOM fixes family, length, supply voltage, colour system, control protocol, ingress rating and per-model compliance documentation.

Key points

  • A facade lighting BOM draws on 5 product catalogues with 98 model entries plus a separate 53-item co-extruded flexible file.
  • Supply, colour, control, ingress and optics are independent BOM lines: DC24V, 1800–6500K/RGB/RGBW, ON/OFF/TTL/DMX512, IP65/IP68.
  • Documented GD-WW power classes are 18/24 W, 24/36 W and 48/72 W at lengths near 1000 mm.
  • CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model.

Short answer

A facade lighting BOM is the itemised list of fixtures, controls and accessories that a contractor submits for approval before an order. GDXC’s 2026 documentation comprises 5 product catalogues with 98 model entries plus a co-extruded flexible file of 53 items. A complete BOM fixes family, length, supply voltage, colour system, control protocol, ingress rating and per-model compliance documentation.

The checklist, line by line

A BOM is a control document, not a shopping list. Each line below must carry an explicit value; a line left as per catalogue will be interpreted differently by the supplier, the installer and the client’s engineer. The project BOM and QA review is where these values are reconciled.

BOM lineDocumented optionsConfirmation point
Product familyGD-L / GD-U, GD-WW / GD-W, GD-FL / GD-B / GD-BF, GD-P / GD-PM, GD-IG / GD-BL / GD-BWPer model
Length1000 / 500 / 260 mm common lengthsPer elevation drawing
SupplyDC24V most low-voltage models; AC220V some floodlightsPer model
ColourSingle-colour 1800–6500K, RGB, RGBWPer model
ControlON/OFF, TTL, DMX512Fixed at order stage
Beam angle10°, 15°, 30°, 45°, 60°, 10×30°, 10×45°, 10×60°, 20×60°Fitted optic, per model
IngressIP65 most outdoor models; IP68 underwater itemsPer model and per project
Housing6063 aluminium, 4 mm silk-screen round-hole glass on relevant modelsPer model
DocumentationPer-model compliance documentsScope confirmed per project

The last line is easy to omit and expensive to fix later. Colour, control and supply are independent, so a single part number that does not spell them out is not a complete BOM line.

Source documents and model entries

The 2026 documentation set comprises 5 product catalogues with 98 model entries. A BOM that mixes rigid fixtures with flexible strip draws on a second, separate file, which is where omissions usually start.

Product familySeries prefixModel entries
Architectural linear lightsGD-L / GD-U10
LED wall washersGD-WW / GD-W20
LED floodlightsGD-FL / GD-B / GD-BF29
In-ground and underwater lightsGD-IG / GD-BL / GD-BW12
Pixel point lightsGD-P / GD-PM27
Total—98

The co-extruded flexible file holds 53 items: 48 neon flex strips, 2 wall-washer strips and 3 ultra-thin rigid bars. Sections run from 6×6 mm to 20×20 mm, with a 120° emitting angle and documented weights of 43.5 / 57 / 109 g/m. Pixel point lights are documented at 36/64/100/144/256/400 points per square metre, which affects controller capacity even though density is a layout decision made by the client’s designer. Flexible linear lighting is the page to cross-check for strip items.

Fixture lines: size, power and optics

Where a rigid wall washer is specified, use the documented dimensions and power classes rather than a generic wattage. The GD-WW3524 is W35 × H24 × L1002 mm at 18/24 W, the GD-WW4025 is W40 × H25 × L1003 mm at 24/36 W, and the GD-WW6036 is W60 × H36 × L1000 mm at 48/72 W.

ModelW × H × L (mm)Power (W)BOM note
GD-WW3524W35 × H24 × L100218 / 24Discrete driver and thermal design
GD-WW4025W40 × H25 × L100324 / 36Discrete driver and thermal design
GD-WW6036W60 × H36 × L100048 / 72Discrete driver and thermal design

A 24/36 W unit is not a dimmed 48/72 W unit, so substituting one for the other changes the driver line. Beam angle is a separate optical line and cannot be tuned at commissioning. How to specify linear LED light for building outlines covers the linear alternative, and LED wall washers lists the family.

Electrical, colour and control lines

These lines travel together in a submittal but are specified separately. Most low-voltage models are DC24V, AC220V appears on some floodlights, and colour and control determine whether an elevation is static or animated.

SchemeColourControlSupply
Static white facadeSingle-colour 1800–6500KON/OFFDC24V most low-voltage models
Fixed-pattern segmentsSingle-colour 1800–6500K or RGBTTLDC24V most low-voltage models
Per-fixture dimmingSingle-colour 1800–6500K, RGB, RGBWDMX512DC24V most low-voltage models
Colour scenesRGB or RGBWDMX512DC24V most low-voltage models

DMX512 vs TTL vs ON/OFF for architectural lighting compares the protocols, and facade lighting design describes how zones are laid out. ON/OFF and TTL units cannot be re-addressed as DMX512 devices after installation, so this line is the one most often regretted.

Protection, documentation and common errors

Ingress rating and documentation are the lines that protect the submittal at handover. IP65 is documented for most outdoor models, IP68 applies to underwater items, and IP66 is not a published default. IP65 vs IP66 vs IP68 for outdoor lighting sets out the comparison.

Common BOM errorConsequenceCorrection
Writing only a series prefixColour, control and supply left undefinedSpell out each option per model
Assuming the flexible file is inside the 98 catalogue entriesStrip lines missing from submittalCheck the 53-item file separately
Leaving the protocol as ON/OFF when scenes are plannedFixtures cannot be re-addressedSpecify DMX512 at order stage
Omitting the per-model IP test reportRating unconfirmed at handoverRequest per-model compliance documents
Treating the catalogue lifetime figure as a warrantyMisstated commercial termsWrite it as a catalogue-stated figure, not a warranty commitment

Why LED facade fixtures fail in hot climates explains why the thermal review matters alongside the paperwork. The compliance wording available is: “CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model.”

Commercial handling

No fixed lead time, published price or warranty period is provided, and catalogues state 50,000 hours for the source, a catalogue-stated figure, not a warranty commitment. GDXC was established in 2014 and is based in Guangming District, Shenzhen, Guangdong Province, China. It prioritises the Middle East and Southeast Asia while also covering Europe, North America, South America and Africa. Send the completed BOM to chenliang@gdzm-led.com, +86 153 0264 9886 or WhatsApp 8615302649886; final selection, quotation and installation work are confirmed by the client’s engineering personnel.

What we do not cover / Limits

This article is a checklist for exterior architectural and landscape facade lighting submittals only. It does not apply to indoor residential lighting or to road and tunnel main lighting, which are outside GDXC’s scope. GDXC does not sell LED chips, packages or bare light sources and does not publish client drawings. No quantities, take-off, driver count, cable schedule, controller schedule, mounting detail, price, lead time or warranty period is provided here; those must be produced by the client’s engineering personnel from the project drawings. The article does not cover submerged installations using non-IP68 models or AC220V mains floodlighting design. We do not promise unverified certifications, fixed lead times or published prices, and no warranty period is offered. Final fixture selection, quotation and installation work must be confirmed by the client’s own engineering team.

This article describes general practice in outdoor architectural LED lighting. It is not a substitute for a project-specific review — beam angle, IP rating and control mode must be confirmed against the fixture schedule, the elevation and the site conditions.

Questions

Frequently asked

What should be included in a facade lighting BOM?

Include family, model, length, supply voltage, colour system, control protocol, ingress rating, beam angle and per-model documentation, plus driver and controller lines. The documented range spans 98 model entries across 5 catalogues, so the flexible 53-item file must be checked separately. Final quantities come from the client's drawings.

How do I avoid ordering the wrong control protocol for facade lights?

Write ON/OFF, TTL or DMX512 explicitly on each fixture line, because the protocol is fixed at order stage and cannot be changed later. ON/OFF and TTL units cannot be re-addressed as DMX512 devices in the field. Confirm the addressing plan with the client's engineering team before release.

Which IP rating should appear on a facade lighting BOM?

IP65 is documented for most outdoor models and IP68 for underwater items; IP66 is not a published default. State the rating per line and request the per-model IP test report. Submerged installations using non-IP68 models are outside the scope.

Does GDXC publish prices and lead times for BOM items?

No. No fixed lead time, published price or warranty period is published, and final quotation is confirmed per project. Send the BOM to chenliang@gdzm-led.com or WhatsApp 8615302649886. The 50,000 hours figure is a catalogue-stated figure, not a warranty commitment.

Send your facade drawings or lighting effect renders

Share an elevation drawing, an effect render or a draft fixture list. Our project engineers return a fixture BOM, beam-angle and optical distribution suggestions, and DMX512 addressing coordination. Final selection, quotation and installation are confirmed with your technical team.

Chat on WhatsApp