Facade Lighting BOM Checklist for Contractors
Facade lighting BOM checklist for contractors: the lines to confirm, from 98 catalogue entries to DC24V supply, IP ratings and DMX512 control.
GDXC Project Engineering · Published November 1, 2026 · 7 min read
A facade lighting BOM is the itemised list of fixtures, controls and accessories that a contractor submits for approval before an order. GDXC's 2026 documentation comprises 5 product catalogues with 98 model entries plus a co-extruded flexible file of 53 items. A complete BOM fixes family, length, supply voltage, colour system, control protocol, ingress rating and per-model compliance documentation.
Key points
- A facade lighting BOM draws on 5 product catalogues with 98 model entries plus a separate 53-item co-extruded flexible file.
- Supply, colour, control, ingress and optics are independent BOM lines: DC24V, 1800–6500K/RGB/RGBW, ON/OFF/TTL/DMX512, IP65/IP68.
- Documented GD-WW power classes are 18/24 W, 24/36 W and 48/72 W at lengths near 1000 mm.
- CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model.
Short answer
A facade lighting BOM is the itemised list of fixtures, controls and accessories that a contractor submits for approval before an order. GDXC’s 2026 documentation comprises 5 product catalogues with 98 model entries plus a co-extruded flexible file of 53 items. A complete BOM fixes family, length, supply voltage, colour system, control protocol, ingress rating and per-model compliance documentation.
The checklist, line by line
A BOM is a control document, not a shopping list. Each line below must carry an explicit value; a line left as per catalogue will be interpreted differently by the supplier, the installer and the client’s engineer. The project BOM and QA review is where these values are reconciled.
| BOM line | Documented options | Confirmation point |
|---|---|---|
| Product family | GD-L / GD-U, GD-WW / GD-W, GD-FL / GD-B / GD-BF, GD-P / GD-PM, GD-IG / GD-BL / GD-BW | Per model |
| Length | 1000 / 500 / 260 mm common lengths | Per elevation drawing |
| Supply | DC24V most low-voltage models; AC220V some floodlights | Per model |
| Colour | Single-colour 1800–6500K, RGB, RGBW | Per model |
| Control | ON/OFF, TTL, DMX512 | Fixed at order stage |
| Beam angle | 10°, 15°, 30°, 45°, 60°, 10×30°, 10×45°, 10×60°, 20×60° | Fitted optic, per model |
| Ingress | IP65 most outdoor models; IP68 underwater items | Per model and per project |
| Housing | 6063 aluminium, 4 mm silk-screen round-hole glass on relevant models | Per model |
| Documentation | Per-model compliance documents | Scope confirmed per project |
The last line is easy to omit and expensive to fix later. Colour, control and supply are independent, so a single part number that does not spell them out is not a complete BOM line.
Source documents and model entries
The 2026 documentation set comprises 5 product catalogues with 98 model entries. A BOM that mixes rigid fixtures with flexible strip draws on a second, separate file, which is where omissions usually start.
| Product family | Series prefix | Model entries |
|---|---|---|
| Architectural linear lights | GD-L / GD-U | 10 |
| LED wall washers | GD-WW / GD-W | 20 |
| LED floodlights | GD-FL / GD-B / GD-BF | 29 |
| In-ground and underwater lights | GD-IG / GD-BL / GD-BW | 12 |
| Pixel point lights | GD-P / GD-PM | 27 |
| Total | — | 98 |
The co-extruded flexible file holds 53 items: 48 neon flex strips, 2 wall-washer strips and 3 ultra-thin rigid bars. Sections run from 6×6 mm to 20×20 mm, with a 120° emitting angle and documented weights of 43.5 / 57 / 109 g/m. Pixel point lights are documented at 36/64/100/144/256/400 points per square metre, which affects controller capacity even though density is a layout decision made by the client’s designer. Flexible linear lighting is the page to cross-check for strip items.
Fixture lines: size, power and optics
Where a rigid wall washer is specified, use the documented dimensions and power classes rather than a generic wattage. The GD-WW3524 is W35 × H24 × L1002 mm at 18/24 W, the GD-WW4025 is W40 × H25 × L1003 mm at 24/36 W, and the GD-WW6036 is W60 × H36 × L1000 mm at 48/72 W.
| Model | W × H × L (mm) | Power (W) | BOM note |
|---|---|---|---|
| GD-WW3524 | W35 × H24 × L1002 | 18 / 24 | Discrete driver and thermal design |
| GD-WW4025 | W40 × H25 × L1003 | 24 / 36 | Discrete driver and thermal design |
| GD-WW6036 | W60 × H36 × L1000 | 48 / 72 | Discrete driver and thermal design |
A 24/36 W unit is not a dimmed 48/72 W unit, so substituting one for the other changes the driver line. Beam angle is a separate optical line and cannot be tuned at commissioning. How to specify linear LED light for building outlines covers the linear alternative, and LED wall washers lists the family.
Electrical, colour and control lines
These lines travel together in a submittal but are specified separately. Most low-voltage models are DC24V, AC220V appears on some floodlights, and colour and control determine whether an elevation is static or animated.
| Scheme | Colour | Control | Supply |
|---|---|---|---|
| Static white facade | Single-colour 1800–6500K | ON/OFF | DC24V most low-voltage models |
| Fixed-pattern segments | Single-colour 1800–6500K or RGB | TTL | DC24V most low-voltage models |
| Per-fixture dimming | Single-colour 1800–6500K, RGB, RGBW | DMX512 | DC24V most low-voltage models |
| Colour scenes | RGB or RGBW | DMX512 | DC24V most low-voltage models |
DMX512 vs TTL vs ON/OFF for architectural lighting compares the protocols, and facade lighting design describes how zones are laid out. ON/OFF and TTL units cannot be re-addressed as DMX512 devices after installation, so this line is the one most often regretted.
Protection, documentation and common errors
Ingress rating and documentation are the lines that protect the submittal at handover. IP65 is documented for most outdoor models, IP68 applies to underwater items, and IP66 is not a published default. IP65 vs IP66 vs IP68 for outdoor lighting sets out the comparison.
| Common BOM error | Consequence | Correction |
|---|---|---|
| Writing only a series prefix | Colour, control and supply left undefined | Spell out each option per model |
| Assuming the flexible file is inside the 98 catalogue entries | Strip lines missing from submittal | Check the 53-item file separately |
| Leaving the protocol as ON/OFF when scenes are planned | Fixtures cannot be re-addressed | Specify DMX512 at order stage |
| Omitting the per-model IP test report | Rating unconfirmed at handover | Request per-model compliance documents |
| Treating the catalogue lifetime figure as a warranty | Misstated commercial terms | Write it as a catalogue-stated figure, not a warranty commitment |
Why LED facade fixtures fail in hot climates explains why the thermal review matters alongside the paperwork. The compliance wording available is: “CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model.”
Commercial handling
No fixed lead time, published price or warranty period is provided, and catalogues state 50,000 hours for the source, a catalogue-stated figure, not a warranty commitment. GDXC was established in 2014 and is based in Guangming District, Shenzhen, Guangdong Province, China. It prioritises the Middle East and Southeast Asia while also covering Europe, North America, South America and Africa. Send the completed BOM to chenliang@gdzm-led.com, +86 153 0264 9886 or WhatsApp 8615302649886; final selection, quotation and installation work are confirmed by the client’s engineering personnel.
What we do not cover / Limits
This article is a checklist for exterior architectural and landscape facade lighting submittals only. It does not apply to indoor residential lighting or to road and tunnel main lighting, which are outside GDXC’s scope. GDXC does not sell LED chips, packages or bare light sources and does not publish client drawings. No quantities, take-off, driver count, cable schedule, controller schedule, mounting detail, price, lead time or warranty period is provided here; those must be produced by the client’s engineering personnel from the project drawings. The article does not cover submerged installations using non-IP68 models or AC220V mains floodlighting design. We do not promise unverified certifications, fixed lead times or published prices, and no warranty period is offered. Final fixture selection, quotation and installation work must be confirmed by the client’s own engineering team.
This article describes general practice in outdoor architectural LED lighting. It is not a substitute for a project-specific review — beam angle, IP rating and control mode must be confirmed against the fixture schedule, the elevation and the site conditions.