How to Read a Photometric Specification
How to read a photometric specification for facade lighting: beam angles, intensity distribution, 6063 aluminium optics and catalogue limits.
GDXC Project Engineering · Published November 13, 2026 · 7 min read
A photometric specification is the measured description of how a luminaire distributes light in space, including its beam angle, intensity distribution and the conditions of measurement. For GDXC facade fixtures the documented beam set is 10°, 15°, 30°, 45°, 60° and asymmetric 10×30°, 10×45°, 10×60°, 20×60°, fitted to 6063 aluminium profiles with DC24V on most low-voltage models.
Key points
- A photometric specification describes beam angle and intensity distribution; documented angles are 10°, 15°, 30°, 45°, 60° and 10×30°, 10×45°, 10×60°, 20×60°.
- Beam angle is fixed by the optic fitted to the 6063 aluminium profile at order stage, not tuned at commissioning.
- The documented photometric parameters are beam angles; no lumen, candela or lux values are published here.
- IP65, DC24V, 1800–6500K/RGB/RGBW and ON/OFF/TTL/DMX512 are separate lines from photometric data.
Short answer
A photometric specification is the measured description of how a luminaire distributes light in space, including its beam angle, intensity distribution and the conditions of measurement. For GDXC facade fixtures the documented beam set is 10°, 15°, 30°, 45°, 60° and asymmetric 10×30°, 10×45°, 10×60°, 20×60°, fitted to 6063 aluminium profiles with DC24V on most low-voltage models.
What a photometric specification contains
A photometric specification describes the shape of a luminaire’s light distribution and the conditions under which it was measured. It is the document that turns a beam label into a layout. This article explains how to read one against the parameters GDXC actually documents, and it deliberately publishes no lumen, candela or lux figure, because none is given in the company fact set.
| Field in a specification | What to look for | Documented value or limit here |
|---|---|---|
| Beam angle | Angular width and symmetry | 10°, 15°, 30°, 45°, 60°, 10×30°, 10×45°, 10×60°, 20×60° |
| Distribution shape | Symmetric versus asymmetric | Both are documented |
| Housing | Body and optical window | 6063 aluminium, 4 mm silk-screen round-hole glass on relevant models |
| Supply | Operating voltage | DC24V most low-voltage models; AC220V some floodlights |
| Colour | Emitter system | Single-colour 1800–6500K, RGB, RGBW |
| Control | Protocol | ON/OFF, TTL, DMX512 |
| Ingress | Enclosure rating | IP65 most outdoor models; IP68 underwater items |
The important habit is to read the beam angle and the housing together. An angle of 10×60° describes a distribution, but the 6063 aluminium profile and the fitted optic decide whether that distribution can be held across a run of 1000 / 500 / 260 mm units.
Reading the documented beam set
GDXC documents a discrete beam set rather than a continuous range. Symmetric values spread light evenly around the axis; asymmetric values are written as two numbers and bias the distribution along the tall dimension of a facade.
| Beam angle | Type | How to read it on an elevation |
|---|---|---|
| 10° | Symmetric | Tight column or reveal |
| 15° | Symmetric | Narrow bay |
| 30° | Symmetric | Standard wall wash |
| 45° | Symmetric | Short setback |
| 60° | Symmetric | Low, broad surface |
| 10×30° | Asymmetric | Medium-height facade |
| 10×45° | Asymmetric | Tall facade |
| 10×60° | Asymmetric | Very tall facade |
| 20×60° | Asymmetric | Wide and tall surface |
How to choose a beam angle for facade lighting sets out the selection logic. Beam angle is fixed by the optic fitted to the 6063 aluminium profile at order stage, so a photometric file cannot be made to describe a different spread by re-aiming the fixture; re-aiming only moves where the existing distribution lands.
Asymmetric notation and orientation
An asymmetric angle such as 10×60° is normally read as a horizontal spread followed by a vertical spread. That notation is why asymmetric optics are used on tall facades in the Middle East and Southeast Asia, which GDXC prioritises, as well as in Europe, North America, South America and Africa.
| Asymmetric angle | Reading | Consequence if orientation is reversed |
|---|---|---|
| 10×30° | Narrow across, medium up | Upper wall under-lit |
| 10×45° | Narrow across, tall up | Beam spills sideways |
| 10×60° | Narrow across, very tall up | Lower wall over-lit |
| 20×60° | Wider across, very tall up | Uneven overlap between units |
Orientation is a drawing decision, not a catalogue value. The client’s designer must confirm which axis is vertical on each elevation, because the same 10×60° optic mounted on its side produces a different result. Facade lighting design describes the layout review; what is an LED wall washer defines the fixture class that most often carries these optics.
What is and is not published
Being explicit about the boundary is part of reading a specification correctly. The table below separates parameters that are documented from values that must come from the client’s own calculations.
| Parameter | Status | Where it comes from |
|---|---|---|
| Beam angles | Documented | 10° to 60° symmetric and 10×30° to 20×60° asymmetric |
| Lengths | Documented | 1000 / 500 / 260 mm common lengths |
| GD-WW power | Documented | 18/24 W, 24/36 W, 48/72 W |
| GD-WW dimensions | Documented | W35 × H24 × L1002 mm, W40 × H25 × L1003 mm, W60 × H36 × L1000 mm |
| Colour and control | Documented | 1800–6500K, RGB, RGBW; ON/OFF, TTL, DMX512 |
| Lumen, candela, lux values | Not published | Client’s photometric calculation |
| Illuminance target and spacing | Not published | Client’s elevation drawing |
| Lumen depreciation curve | Not published | Not supplied |
The catalogues state 50,000 hours for the source, a catalogue-stated figure, not a warranty commitment, and that figure is not a lumen depreciation curve. The 2026 documentation set comprises 5 product catalogues with 98 model entries: 10 architectural linear lights, 20 wall washers, 29 floodlights, 12 in-ground and underwater lights, and 27 pixel point lights. A separate co-extruded file holds 53 items: 48 neon flex strips, 2 wall-washer strips and 3 ultra-thin rigid bars, with sections from 6×6 mm to 20×20 mm, a 120° emitting angle and weights of 43.5 / 57 / 109 g/m.
Separate lines that are not photometric
It is easy to read electrical and ingress values as if they were photometric results. They are not; they are independent BOM lines, and they do not change the beam shape.
| BOM line | Documented options | Effect on beam shape |
|---|---|---|
| Supply | DC24V most low-voltage models; AC220V some floodlights | None |
| Colour | Single-colour 1800–6500K, RGB, RGBW | None |
| Control | ON/OFF, TTL, DMX512 | None |
| Ingress | IP65 most outdoor models; IP68 underwater items | None |
| Pixel density | 36/64/100/144/256/400 points per square metre | Layout resolution, not beam shape |
DMX512 vs TTL vs ON/OFF for architectural lighting covers protocol, RGB vs RGBW vs single colour for facades covers colour, why LED facade fixtures fail in hot climates covers thermal behaviour, and thermal and materials covers the housing review. LED wall washers lists the family.
Documentation and commercial handling
The compliance wording available is: “CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model.” No certification number, fixed lead time, published price or warranty period is provided, and the 50,000 hours figure is a catalogue-stated figure, not a warranty commitment. GDXC was established in 2014 and is based in Guangming District, Shenzhen, Guangdong Province, China. Enquiries: chenliang@gdzm-led.com, +86 153 0264 9886, WhatsApp 8615302649886.
What we do not cover / Limits
This article explains how to read photometric parameters for exterior architectural and landscape facade lighting only. It does not apply to indoor residential lighting or to road and tunnel main lighting, which are outside GDXC’s scope. GDXC does not sell LED chips, packages or bare light sources and does not publish client drawings. No lumen, candela, lux, illuminance, uniformity, spacing, aiming schedule or lumen depreciation value is published here; all layout calculations must be produced by the client’s engineering personnel from project-specific data. The article does not cover submerged installations using non-IP68 models or AC220V mains floodlighting design. We do not promise unverified certifications, fixed lead times or published prices, and no warranty period is offered; the 50,000 hours figure is a catalogue-stated figure, not a warranty commitment. Final fixture selection, quotation and installation work must be confirmed by the client’s own engineering team.
This article describes general practice in outdoor architectural LED lighting. It is not a substitute for a project-specific review — beam angle, IP rating and control mode must be confirmed against the fixture schedule, the elevation and the site conditions.