How to Choose a Beam Angle for Facade Lighting

How to choose a beam angle for facade lighting: symmetric vs asymmetric optics, 10°–60° options, and when to use 10×60° on tall buildings.

GDXC Project Engineering · Published October 8, 2026 · 6 min read

Short answer

A beam angle is the angular spread of a luminaire's light output, measured between the directions where intensity falls to half its peak. For facade lighting it determines how far from a wall a fixture must sit and how evenly adjacent units blend. Documented options are 10°, 15°, 30°, 45°, 60° symmetric and 10×30°, 10×45°, 10×60°, 20×60° asymmetric, applied to 6063 aluminium profiles at 1000 / 500 / 260 mm lengths.

Key points

  • Beam angle is chosen from the documented set of 10°, 15°, 30°, 45°, 60° and 10×30°, 10×45°, 10×60°, 20×60°, not from a continuous range.
  • Symmetric angles suit even setbacks; asymmetric 10×45°, 10×60° and 20×60° bias output up a tall facade.
  • Wall washers, linear lights and floodlights share one beam vocabulary across 98 catalogue model entries.
  • Power classes 18/24 W, 24/36 W and 48/72 W are decided separately from the optic.

Short answer

A beam angle is the angular spread of a luminaire’s light output, measured between the directions where intensity falls to half its peak. For facade lighting it determines how far from a wall a fixture must sit and how evenly adjacent units blend. Documented options are 10°, 15°, 30°, 45°, 60° symmetric and 10×30°, 10×45°, 10×60°, 20×60° asymmetric, applied to 6063 aluminium profiles at 1000 / 500 / 260 mm lengths.

Why beam angle is a geometric decision

Beam angle is not a brightness setting. It fixes the shape of the light distribution that leaves the optic, and everything downstream, including mounting offset, spacing between fixtures and the number of units on a run, follows from that shape. A specifier who treats 10° and 60° as interchangeable dimming choices will get a scalloped wall at one end and wasted spill light at the other.

The documented products put the optic inside an extruded 6063 aluminium profile with a 4 mm silk-screen round-hole glass window on relevant models. That construction is rigid: the optic, the sealing gasket and the thermal path are designed as one assembly. It is why beam angle is fixed at order stage and cannot be tuned on site, and why a DC24V wall washer and an AC220V floodlight may share a beam label while producing very different results on the same wall. Optical intent and thermal capacity are settled together, not in sequence.

The documented beam set

The catalogues list a discrete set of beam angles rather than a continuous range. Symmetric values spread light evenly around the axis; asymmetric values, written as horizontal × vertical, bias the distribution along the tall dimension of a facade.

Beam angleFamilyWhere it is normally applied
10°SymmetricColumn, narrow reveal, accent
15°SymmetricTall narrow bay
30°SymmetricStandard wall wash
45°SymmetricShort setback, broad wall
60°SymmetricLow, broad surface
10×30°AsymmetricMedium-height facade
10×45°AsymmetricTall facade
10×60°AsymmetricVery tall facade
20×60°AsymmetricWide and tall surface

The same vocabulary is used across the 98 model entries in the 2026 catalogues: 10 architectural linear lights, 20 wall washers, 29 floodlights, 12 in-ground and underwater lights, and 27 pixel point lights. That shared vocabulary helps when a single elevation mixes architectural linear lights with LED wall washers, but it does not mean a given angle is stocked on every model. The angle-to-model mapping is confirmed per project rather than assumed from a series prefix.

Matching the angle to the elevation

Selection starts from the shape of the surface, not from the fixture catalogue. The table below frames the decision as a set of conditions to verify on the drawing; no setback distance or spacing figure is assumed here, because those are derived by the client’s designer from the photometric data.

Elevation conditionBeam family to considerConsequence if chosen incorrectly
Tall plane, close to facadeAsymmetric 10×45°, 10×60°, 20×60°Symmetric optics leave the upper wall dark
Even setback, moderate heightSymmetric 30°, 45°Narrow 10° or 15° optics create visible scallops
Narrow column or revealSymmetric 10°, 15°Wide optics spill onto adjacent surfaces
Low, broad wallSymmetric 60°Narrow optics over-light a small patch
Wide and tall surfaceAsymmetric 20×60°Coverage gaps between adjacent units

Lengths also enter the spacing calculation. Common lengths are 1000 / 500 / 260 mm, and the GD-WW3524 at W35 × H24 × L1002 mm, GD-WW4025 at W40 × H25 × L1003 mm and GD-WW6036 at W60 × H36 × L1000 mm all sit near the 1000 mm point. Shorter 500 mm or 260 mm units change the joint pattern between fixtures, which stays visible on a continuous wash even when the beam angle is unchanged.

What beam angle does not decide

Beam angle is one line in a specification. It does not set power, colour, ingress protection or control protocol, and those lines can be combined independently as far as the documented options allow.

ParameterDocumented optionsIndependent of beam angle?
Power18/24 W, 24/36 W, 48/72 W on GD-WW modelsYes, discrete driver and thermal designs
SupplyDC24V most low-voltage models, AC220V some floodlightsYes
ColourSingle-colour 1800–6500K, RGB, RGBWYes
ControlON/OFF, TTL, DMX512Yes, fixed at order stage
IngressIP65 most outdoor models, IP68 underwater itemsYes

A DMX512 RGBW wall washer and a single-colour ON/OFF unit can therefore carry the same 10×60° optic. Control behaviour is handled under DMX512 control systems, while the layout itself belongs to facade lighting design. The catalogues state 50,000 hours for the source, a catalogue-stated figure, not a warranty commitment, and that figure is unaffected by the optic chosen.

How to verify the choice before ordering

Photometric data is the check that turns an angle into a layout. How to read a photometric specification explains the intensity distribution and the beam definition used in manufacturer files. For a facade that combines washes, outlines and colour scenes, what is an LED wall washer defines the fixture class, and how to specify linear LED light for building outlines covers the linear alternative. Colour-system implications are set out in RGB vs RGBW vs single colour for facades.

Before the BOM is released, the compliance wording available is: “CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model.” Requests can be sent to chenliang@gdzm-led.com, +86 153 0264 9886 or WhatsApp 8615302649886. GDXC was established in 2014 and is based in Guangming District, Shenzhen, Guangdong Province, China, and prioritises the Middle East and Southeast Asia while also supplying Europe, North America, South America and Africa.

What we do not cover / Limits

This article covers beam-angle selection for exterior architectural and landscape facade lighting only. It does not apply to indoor residential lighting or to road and tunnel main lighting, which are outside GDXC’s scope, and it does not cover luminaire photometry for general area lighting. GDXC does not sell LED chips, packages or bare light sources and does not publish client drawings. No setback distance, fixture spacing, illuminance target or aiming schedule is provided here, because those must be calculated by the client’s engineering personnel from project-specific photometric data. The article does not cover submerged installations using non-IP68 models or AC220V mains floodlighting design. We do not promise unverified certifications, fixed lead times or published prices, and no warranty period is offered; the 50,000 hours figure is a catalogue-stated figure, not a warranty commitment. Final fixture selection, quotation and installation work must be confirmed by the client’s own engineering team.

This article describes general practice in outdoor architectural LED lighting. It is not a substitute for a project-specific review — beam angle, IP rating and control mode must be confirmed against the fixture schedule, the elevation and the site conditions.

Questions

Frequently asked

What beam angle should I use for a tall building facade?

Use an asymmetric angle such as 10×45°, 10×60° or 20×60°, which pushes more light toward the upper part of the wall. Symmetric 30° or 45° optics suit lower or evenly set-back surfaces. Confirm setback and aiming on site with the client's engineering team.

Is a 10° or 60° beam better for wall washing?

Neither is universally better: 10° concentrates light on a narrow column while 60° covers a low, broad surface. The choice depends on setback and facade height, and both come from the same documented beam set. A photometric file, not the angle alone, decides the final layout.

Can I change the beam angle of an LED wall washer after installation?

No. Beam angle is set by the optic fitted to the 6063 aluminium profile at order stage, alongside the 18/24 W, 24/36 W or 48/72 W power class. Re-aiming changes where the beam lands but not its spread.

Which beam angles does GDXC document for DMX512 RGBW fixtures?

The documented set is 10°, 15°, 30°, 45°, 60°, 10×30°, 10×45°, 10×60° and 20×60°, and it applies across ON/OFF, TTL and DMX512 control versions. Colour system and control protocol do not change the optics. Confirm the exact angle per model in the project BOM.